TodaySynced
Annual landlord gas safety#4814 · Landlord gas safety · 08:30Job done at 09:12The report and CP12 certificate went to Ashgrove Lettings. The office has the invoice to approve.
Where
Flat 4, Castle Quay 4 Castle Quay, Castlefield, M15 4NTAccess: Key safe by the bin storeTenant: Jess MoranEquipment: Worcester Bosch Greenstar 30i + hobRisk assessment · Gas work
Tap whether each one is here today. The controls are what you do about it.Gas escapeTightness test before and after the work. No smoking or naked flames. If you smell gas, make safe and follow the Gas Industry Unsafe Situations Procedure
Carbon monoxide from flues and appliancesCarry a CO monitor. Flue and combustion checks on every appliance you work on
Hot pipes, water and surfacesLet the system cool, drain down where needed, gloves for hot parts
Lofts, cupboards and tight spacesBoards and a light in lofts. Check the space is safe to work in before you start
Electrics on the applianceIsolate the appliance and prove dead before taking covers off
Method and PPE
- Arrive, introduce yourself and find the meter and the appliance
- Tightness test before starting
- Isolate gas and electrics to the appliance
- Carry out the work to the manufacturer's instructions and the Gas Safety Regulations
- Tightness test, flue and combustion checks after the work
- Show the customer, leave the paperwork and hand back
Landlord gas safety checklist · 6 of 6
Tenant signature
Forms for this job
Faults found · 2
Each one goes on the repair quote with its photo.ARGas fire, lounge (Flat 4)Failed the spillage test · made safe
NCSKitchen (Flat 4)No CO alarm in the room with the boiler