TodaySynced
No heating, tenant has a newborn#4891 · Breakdown · Not booked · EmergencyBefore you go
Flat 9, Ancoats Works: newborn in the home.Ideal Logic Max C30, fitted 2021 (5 years old). Last serviced 7 months ago.Newborn in the home. This is a priority, keep them updated.Gas safety and repairs. 4 hour attend, be there by 12:52.They owe £1,840. Don't bring it up, the office is chasing it.On a plan: gas safety, 3 flats.Where
Flat 9, Ancoats Works 9 Ancoats Works, Ancoats, M4 6DEAccess: Concierge holds keysTenant: Lucy HartEquipment: Ideal Logic Max C30Risk assessment · Gas work
Tap whether each one is here today. The controls are what you do about it.Gas escapeTightness test before and after the work. No smoking or naked flames. If you smell gas, make safe and follow the Gas Industry Unsafe Situations Procedure
Carbon monoxide from flues and appliancesCarry a CO monitor. Flue and combustion checks on every appliance you work on
Hot pipes, water and surfacesLet the system cool, drain down where needed, gloves for hot parts
Lofts, cupboards and tight spacesBoards and a light in lofts. Check the space is safe to work in before you start
Electrics on the applianceIsolate the appliance and prove dead before taking covers off
Method and PPE
- Arrive, introduce yourself and find the meter and the appliance
- Tightness test before starting
- Isolate gas and electrics to the appliance
- Carry out the work to the manufacturer's instructions and the Gas Safety Regulations
- Tightness test, flue and combustion checks after the work
- Show the customer, leave the paperwork and hand back
Answer every hazard above, then sign here.
Breakdown checklist · 0 of 8
Available once you've arrived
Customer signature
Forms for this job
Parts for this job
Ideal Logic diverter valveNot sorted yet · Needed