What you need to know
From Northside Heating & Electrical's own risk assessment.Gas escape: Tightness test before and after the work. No smoking or naked flames. If you smell gas, make safe and follow the Gas Industry Unsafe Situations Procedure
Carbon monoxide from flues and appliances: Carry a CO monitor. Flue and combustion checks on every appliance you work on
Hot pipes, water and surfaces: Let the system cool, drain down where needed, gloves for hot parts
Lofts, cupboards and tight spaces: Boards and a light in lofts. Check the space is safe to work in before you start
Electrics on the appliance: Isolate the appliance and prove dead before taking covers off
Step 1: Arrive, introduce yourself and find the meter and the appliance
Step 2: Tightness test before starting
Step 3: Isolate gas and electrics to the appliance
Step 4: Carry out the work to the manufacturer's instructions and the Gas Safety Regulations
Step 5: Tightness test, flue and combustion checks after the work
Step 6: Show the customer, leave the paperwork and hand back
PPE: Safety boots, Gloves, CO monitor
1. Lofts, cupboards and tight spaces. What's the control?
2. Carbon monoxide from flues and appliances. What's the control?
3. Hot pipes, water and surfaces. What's the control?
4. Which of these comes first in the method?
5. Which of these is on the PPE list?