5-year electrical inspection
#4828 · Electrical inspection (EICR) · Kingsway Dental · came in by email on 14 Nov at 09:00
On sitePass to another firm
✓Logged✓Booked✓On the way4On site5Job done6Invoiced
Change who or when
Checklist · Electrical inspection
2 of 6 doneArrived
tickSafe isolation done
tickPhoto of the consumer unit
photoRequiredCircuits tested
numberRequiredFaults logged (C1, C2, C3, FI)Each one goes on the repair quote with its photo
textCustomer signature
signatureRequiredRisk assessment · Electrical work
Must be signed before starting6 hazards to check. The engineer fills it in and signs on the phone before they can start.
Electrical installation condition report
Filled in on siteThe engineer fills this in on their phone. It's sent to the customer as soon as the job is closed. The next one is due 60 months later, from the date on the certificate.
Another certificate for this job
PAT test certificate and registerMinor electrical installation works certificateElectrical installation certificateElectrical danger notificationEmergency lighting inspection and test certificate (BS 5266-1)Fire alarm inspection and servicing certificate (BS 5839-1)Fire alarm installation and commissioning certificate (BS 5839-1)Fire extinguisher service certificate (BS 5306-3)EV charger installation certificate
Forms
Site safety checkNot filled in
Customer handoverNot filled in
Thermal imaging surveyNot filled in
Tasks
0 to doChat
Only your team sees thisNo messages yet. The engineer on this job sees them on their phone.
Handover notes
For whoever goes nextJob report and invoice line
Draft, to approveEverything that's happened
ArrivedTom Hughes · 17 Nov 10:03
Live profit
-£592 · -247%- Price
- £240
- Parts and materials
- £730
- Labour
- £102
Under your 20% alert line. Check the parts and time before more goes on it.
Extra work
Engineers can agree up to £150 on siteV-006: Customer wants the rest of the job done today while we're here: consumer unit changeTom Hughes · costs £730
£1,140Needs the officeLog extra work or a daywork
Project and subcontractor
Summary
Job #4828: Electrical inspection (EICR), 5-year electrical inspection. Status On site. Priority normal. For Kingsway Dental at 220 Kingsway, Burnage, M19 2LP. Tom Hughes is on it. Booked 17 Nov. Checklist 2 of 6 done.Example business: from the sample records.
Did it make money? (so far)
£121 · 50%- Billed
- £240
- Labour
- £71 · 2h 5m of 3h booked
- Travel
- £36 · 45 min
- Parts
- £12
45 min travel each way
Before you go
What the engineer seesKingsway Dental: 10-year-old Hager.
Last visit 16 Nov: water heater service, Jake.
Hager 18-way RCBO board, fitted 2016 (10 years old). Last inspected 57 months ago.
Older than most. If it's costing them in repairs, offer a replacement quote. There's a button on the job.
Access: Park at the rear.
They owe £312. Don't bring it up, the office is chasing it.
On a plan: electrical inspection.
Dispatch
PreventiveLikely value: £240 · from price on the job
Scheduling goal: Balanced
Booked for 180 min. Tom usually takes 170 min (28 past jobs)
Exact location
Follow-on jobs
Days and crew
Details
- When
- 17 Nov, 10:00 (3h)
- Engineer
- THTom Hughes · Van 3
- Value
- £240
Customer
- Name
- Kingsway Dental
- Phone
- 0161 496 0295
- Owes
- £312
Site
- Address
- 220 Kingsway, Burnage, M19 2LP
- Access
- Park at the rear
Equipment
- Item
- Hager 18-way RCBO board
- Type
- Consumer unit
- Installed
- 2016
- Next due
- Due in 125 days
- Last certificate
- EICR-1102