Northside Heating & Electrical · Field services

The engineer app

For engineers at Northside Heating & Electrical. Read it once, then keep it on your phone. Everything here uses the same words as the app.

Getting the app on your phone

  1. On your phone, go to one.agentryx.io and put in your email. You get a sign-in link by email, so there’s no password.
  2. Add it to your home screen so it opens like any other app. On an iPhone, open it in Safari, tap Share, then Add to Home Screen. On Android, open it in Chrome, tap the three dots, then Add to Home screen.
  3. When it asks to send you notifications, say yes. That’s how you hear about new jobs and changes.
  4. Add a photo of yourself at the bottom of the home page. Customers see it with your first name when you’re on the way.

Your day list

On screen: Home

The app opens on today. The Next up card at the top is your next job, with the address and access notes. Below it is today’s route on a map and the full list, with finished jobs at the bottom.

Tap any job to open it. Before you go tells you what happened there last time and anything to watch for. Directions opens your maps app.

Your hours are worked out from what you tap. Your first On my way clocks you in and Job done on your last job clocks you out, so you don’t need to fill in a timesheet.

The day before each visit, the customer gets a text asking them to confirm. The office sees who has and who hasn’t. If someone asks to rebook, the office moves it and it drops off your list. If a booking was only pencilled in on a call, you won’t see it until the office confirms it.

On my way and running late

  1. Tap On my way when you set off. The customer gets a text with your first name and photo.
  2. Held up? Tap Running late and pick 15, 30 or 45 minutes. They get a text with the new time and the office can see it.
  3. Tap Arrived when you get there.

Sign the risk assessment before you start

Some jobs have a risk assessment and method statement (RAMS). If it has to be signed first, the job won’t let you say you’ve arrived until it’s done.

Go down each hazard and say whether it’s there today. Add anything else on site under Anything else on site today. Read the method and PPE, then sign with your finger. The signed copy is kept on the job with the time and where you were.

Checklists, required steps and photos

Work down the checklist on the job. Steps marked Required have to be done before you can finish. That might be a tick, a reading, a photo or a signature.

Photos. Tap Tap to take a photo. You can draw on it or add an arrow to show the problem, then Use this photo. Mark it as Before or After if it shows the work before you started or once it’s done. Before and after photos go on the report to the customer.

You can talk notes in with the microphone instead of typing.

Certificates on the phone

If the job has a certificate, open it from the job and tap Fill in. You do the full form on the phone: Electrical installation condition report, PAT test certificate and register, Minor electrical installation works certificate, Electrical installation certificate, Fire alarm inspection and servicing certificate (BS 5839-1), Emergency lighting inspection and test certificate (BS 5266-1), Fire alarm installation and commissioning certificate (BS 5839-1), Fire extinguisher service certificate (BS 5306-3), EV charger installation certificate. It saves as you go, even with no signal.

When you’ve finished, tap Check for gaps. It points out anything missing or odd. Fix it, or tap It’s right, leave it.

If you did it in your own certificate app, you can attach the PDF to the job instead. Some job types won’t finish until the certificate is filled in.

Faults and repair quotes

Found something that needs fixing? Tap Log a fault, say what and where, and take a photo. It goes on the repair quote for this job, priced from your price list, and the customer gets it the same day. When they say yes, the repair is booked.

Parts and van stock

Add the parts you used on the job under Parts used. It shows what’s On your van first, then what you’ve used recently. Parts from your van come off its stock by themselves, and the office is told when something gets low.

Need a part you haven’t got? Add it to the job. The office orders it and you’ll see when it’s ready to collect.

Extra work. If the customer asks for more while you’re there, tap Add extra work. Put in what it is, the hours or a fixed price, and the customer’s name to agree it. Under your limit you can save it straight away, and over it, it goes to the office first.

No access

If you can’t get in, tap Can’t get in? on the job. Take a photo that shows it, such as the front door or a locked gate, then tap Mark no access. The time is kept, the office rebooks it, and the customer gets a text to pick a new time.

Finishing a job

When the required steps are done, tap Finish job. The report is written up from what you recorded, and you or the office check it before the customer sees it. Any certificate is issued at the same time.

Electrical and fire certificates

On an EICR or EIC, add each board, then its circuits and readings. Give any observation its code: C1 is danger present, C2 is potentially dangerous, C3 is improvement recommended, and FI is further investigation. C1 and C2 faults go on the repair quote with your photo.

For an EV charger install, fill in the charger certificate on the phone before you finish. It goes to the customer with the report.

For emergency lighting, add each fitting with where it is and its result. They stay on the site for next time.

For PAT testing, record each item with its tag. Failed items are listed with the reason.

The fire alarm and extinguisher forms follow the British Standard layout. Go through every device and section before you sign.

Open jobs to claim

On screen: Open jobs to claim

This shows work nobody is on yet that you can do, with your next free time. Tap Take it or Ask for it, depending on how the office has set it up. If you change your mind, tap Take my name off it.

Ask, manuals and training

Ask answers questions from the firm’s own manuals, fault codes, the history of the equipment and the office’s notes, and shows where each answer came from. For example, “What does fault code F28 mean?”. Manuals and fault codes has the documents themselves.

Training has short lessons made from your own checklists and risk assessments, each with a quick quiz.

Staying safe

Expenses and leave

Expenses. Take a photo of the receipt, put in the amount and what it was for, and send it. The office approves it, and you can see where it’s up to under Yours.

Leave. See what you’ve got left this year, ask for days off, or say you’re off sick. The office approves it.

Working with no signal

Carry on as normal. Today’s jobs are saved on your phone, and everything you do is kept there until you’re back in signal. The badge at the top shows how many things are waiting, then Synced when they’ve gone. Don’t sign out while anything is waiting.

Your checklists

Steps marked required have to be done before the job will finish.

Breakdown, Electrical fault
  • Arrived and introduced yourself (required)
  • Safety check before starting (required)
  • Photo before (required)
  • What was wrong (required)
  • Parts used
  • Photo after (required)
  • Fixed on this visit? (required)
  • Customer signature (required)
Boiler service
  • Arrived (required)
  • Flue checked (required)
  • Working pressure (mbar) (required)
  • Gas rate checked (required)
  • Photo of the boiler and data plate (required)
  • Customer signature (required)
Landlord gas safety
  • Arrived, tenant present (required)
  • Each appliance checked (required)
  • Tightness test passed (required)
  • CO alarm present and tested (required)
  • Photo of each appliance (required)
  • Tenant signature (required)
Electrical inspection (EICR)
  • Arrived (required)
  • Safe isolation done (required)
  • Photo of the consumer unit (required)
  • Circuits tested (required)
  • Faults logged (C1, C2, C3, FI)
  • Customer signature (required)
PAT testing
  • Signed in on site (required)
  • Last year's register loaded (required)
  • Items tested (required)
  • Pass or fail label on every item (required)
  • Failed items taken out of use (required)
  • Site contact signature (required)
Remedial work
  • Signed in on site (required)
  • Safe isolation done (required)
  • Photo before (required)
  • Each fault on the quote fixed (required)
  • Circuits retested (required)
  • Photo after (required)
  • Site contact signature (required)
New circuits or rewire (EIC)
  • Signed in on site (required)
  • Safe isolation done (required)
  • Photo before (required)
  • New circuits tested (required)
  • Photo of the board, labelled (required)
  • Customer shown the board and RCD test
  • Customer signature (required)
Fire alarm service
  • Signed in on site (required)
  • Panel and log book checked (required)
  • Devices tested this visit (required)
  • Standby batteries tested (required)
  • Photo of the panel (required)
  • Responsible person signature (required)
Emergency lighting test
  • Signed in on site (required)
  • Log book checked (required)
  • Luminaires tested (required)
  • Supply restored and charging (required)
  • Photo of any failed fittings
  • Responsible person signature (required)
Fire alarm install or extension
  • Signed in on site (required)
  • Design and zone plan on site (required)
  • Devices fitted and commissioned (required)
  • Cause and effect tested (required)
  • Photo of the panel and zone plan (required)
  • Responsible person signature (required)
Extinguisher service
  • Signed in on site (required)
  • Each extinguisher serviced and labelled (required)
  • Extinguishers serviced (required)
  • Photo of any condemned extinguishers
  • Responsible person signature (required)
EV charger install
  • Arrived, work area protected (required)
  • Safe isolation done (required)
  • Photo of the cut-out and fuse rating (required)
  • Photo of the charger data plate (required)
  • Circuit tested and charger commissioned (required)
  • Customer shown the app and isolation (required)
  • Customer signature (required)
Planned maintenance
  • Signed in on site (required)
  • Scheduled tasks done (required)
  • Defects found
  • Photo evidence
  • Site contact signature
Installation
  • Arrived, work area protected (required)
  • Photo before (required)
  • Serial number of new unit (required)
  • Commissioned and tested (required)
  • Photo after (required)
  • Customer shown how to use it (required)
  • Customer signature (required)
Quote visit
  • Arrived (required)
  • Photos of the work area (required)
  • What the customer wants (required)

Emergencies

Getting help

Tap Report a problem at the top of the app. Say what happened and Agentryx sees it straight away. For anything about a job, use Chat with the office on the job.

See the office guide