TodaySynced
Annual boiler service#4807 · Boiler service · 08:00
Job done at 08:58The report and Service certificate went to Mark Taylor. The office has the invoice to approve.

Where

Mark Taylor 18 Beech Avenue, Sale, M33 2QTEquipment: Worcester Bosch Greenstar 4000

Risk assessment · Gas work

Tap whether each one is here today. The controls are what you do about it.
Gas escapeTightness test before and after the work. No smoking or naked flames. If you smell gas, make safe and follow the Gas Industry Unsafe Situations Procedure
Carbon monoxide from flues and appliancesCarry a CO monitor. Flue and combustion checks on every appliance you work on
Hot pipes, water and surfacesLet the system cool, drain down where needed, gloves for hot parts
Lofts, cupboards and tight spacesBoards and a light in lofts. Check the space is safe to work in before you start
Electrics on the applianceIsolate the appliance and prove dead before taking covers off
Method and PPE
  1. Arrive, introduce yourself and find the meter and the appliance
  2. Tightness test before starting
  3. Isolate gas and electrics to the appliance
  4. Carry out the work to the manufacturer's instructions and the Gas Safety Regulations
  5. Tightness test, flue and combustion checks after the work
  6. Show the customer, leave the paperwork and hand back
PPE: Safety boots, Gloves, CO monitor

Boiler service checklist · 6 of 6

Working pressure (mbar)Not filled in

Customer signature

Signed

Faults found · 0

Each one goes on the repair quote with its photo.

Stuck?

Ask about this equipment, a fault code or the manual. Answers come from your firm's own manuals and records, with where it found them.Ask

Job report

Written by AI from this job's records. Read it, change anything, then approve.

Handover notes

Priya Shah 5 Nov · for every visit here
Side gate sticks, lift it as you push. The isolator is in the cupboard under the stairs, not by the board.
Tom Hughes 16 Nov
Started this yesterday and ran out of time. The parts are in the hall cupboard. It just needs finishing and testing.

Chat with the office

Ellie Burke · 08:05@Dan customer has rung, can you park on the road. The drive is being resurfaced.
Dan Reid · 08:09No problem, will do.

Leave a handover note

Extra work

You can agree up to £150 with the customer. Over that, the office approves it first.
V-003: Lifted and relaid floorboards in two rooms the main contractor had screwed down. Not in the spec.£419.00 · Sent to the customer

Need a hand?

Show the office or the customer what you can see. Send them the link and they join from their phone or computer.

Another certificate for this job

Electrical installation condition reportEICR ›PAT test certificate and registerPAT ›Minor electrical installation works certificateMinor works ›Electrical installation certificateEIC ›Electrical danger notificationDanger notice ›Emergency lighting inspection and test certificate (BS 5266-1)Emergency lighting ›Fire alarm inspection and servicing certificate (BS 5839-1)Fire ›Fire alarm installation and commissioning certificate (BS 5839-1)Fire commissioning ›Fire extinguisher service certificate (BS 5306-3)Extinguishers ›EV charger installation certificateEV charger ›

Service record

Sent to the customer when you finish the job.